8.3.7. Coupling hydraulic actuator

Removal of air

Pumping of system will be required every time after carrying out dismantling and assembly of a hydraulic actuator of coupling.
PERFORMANCE ORDER
1. Fill a tank with the fresh DOT-3 brake fluid (use of the fulfilled liquid is forbidden).
2. Lift a car front.
3. Dress a hose on the cylinder union and release in the capacity filled with brake fluid on 5 cm.
4. Ask the assistant to press a coupling pedal to the full. Unscrew the pumping union, having produced liquid, tighten the union and ask the assistant to release a pedal slowly. Repeat the procedure until the hose does not cease to leave vials of air.
5. When pumping constantly you watch level, without allowing withdrawal of liquid from a tank.