e4035ede

1.3.3.1.3. Check of liquid of the rechargeable battery


Check on lines of level of liquid

Level of liquid (electrolyte) has to be between the top and lower line.

When checking level of liquid check all six cells, and not just one or two.

If level is below the lower line, then add the distilled water.

Check by means of a hydrometer

Check a condition of the rechargeable battery on color of a hydrometer.

Color of a hydrometer
State
Type A
Type B
Green
Blue
Good
Dark
White
Recharge is required. Check the rechargeable battery
Transparent or slightly yellow
Red
Add the distilled water

Addition of the distilled water


Remove ventilating traffic jams

Add the distilled water to cells which need liquid. If the party of the rechargeable battery is closed, check liquid level, looking directly from above in a cell.

Again reliably tighten ventilating traffic jams.