3.4.13. Starter electric motor
1. Traction relay
2. Starter |
3. Vice 4. Switch |
If there are suspicions on malfunction of a chain of a starter, then be convinced that the battery is charged, check purity reliability of fastening of wires, serviceability of the blocking switch of situation Park/Neutral or coupling (on and/m from the manual transmission). Check also serviceability of the relay of a starter (is in the assembly block of the relay in a motor compartment).
If the starter electric motor does not rotate at turn of a key at all, then check tension on the traction relay. If tension is, then remove a starter and check.
At slow rotation of a starter check tension and current at start-up which at not really low temperature, later no more than 10 from later inclusion of a starter have to be respectively not lower than 8,0 B and 250-400 And. If starting current does not correspond to the specified limit, then replace a starter, previously having checked serviceability of wires, connections and the battery.
If tension on a starter is, but the starter does not rotate, then remove a starter for check. For check of a starter collect the scheme, having connected wires the specified conclusions (see rice. Starter conclusions). If the obgonny coupling starts, but the starter does not rotate, then the starter is faulty. If clicks are listened, and the coupling does not start, then either the relay, or a starter are faulty.
Removal
Details of installation of a starter (4-cylinder engine)
1. Socket 2. Starter 3. Power cable |
Details of installation of a starter (6-cylinder engine)
1. Socket 2. Starter 3. Power cable |
PERFORMANCE ORDER | |||||
|
Installation
Installation is carried out upside-down.